Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the acf domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the astra-addon domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131

Notice: Function _load_textdomain_just_in_time was called incorrectly. Translation loading for the woocommerce domain was triggered too early. This is usually an indicator for some code in the plugin or theme running too early. Translations should be loaded at the init action or later. Please see Debugging in WordPress for more information. (This message was added in version 6.7.0.) in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131

Notice: Funkcija _load_textdomain_just_in_time je bila klicana nepravilno. Nalaganje prevodov za domeno astra se je sprožilo prezgodaj. To je običajno znak, da se neka koda v vtičniku ali temi izvaja prezgodaj. Prevodi bi se morali naložiti ob dejanju init ali kasneje. Za več podrobnosti si oglejte razhroščevanje v WordPressu. (To sporočilo je bilo dodano v izdaji 6.7.0.) in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131

Notice: Funkcija _load_textdomain_just_in_time je bila klicana nepravilno. Nalaganje prevodov za domeno astra-addon se je sprožilo prezgodaj. To je običajno znak, da se neka koda v vtičniku ali temi izvaja prezgodaj. Prevodi bi se morali naložiti ob dejanju init ali kasneje. Za več podrobnosti si oglejte razhroščevanje v WordPressu. (To sporočilo je bilo dodano v izdaji 6.7.0.) in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131
CEM MARS 2 – Merel
Deprecated: Funkcija WP_Dependencies->add_data() je bila klicana z argumentom, ki je zastarel od izdaje 6.9.0! IE conditional comments are ignored by all supported browsers. in /home/insignia/merel.idea-studio.si/wp-includes/functions.php on line 6131

CEM MARS 2

Kombinacija zmogljivega in ekonomičnega sistema za mikrovalovni razklop serije vzorcev.

MARS 2 je mikrovalovni sistem za kislinski razklop vzorcev za elementno analizo z ICP-OES, ICP-MS ali AAS. S pomočjo predhodno naloženih metod lahko pripravimo rastlinske vzorce, vzorce tal, živil, farmacevtske izdelke itd.

 

Lastnosti:

• Kompaktna industrijska konstrukcija iz nerjavečega jekla 316

• Večplastna prevleka iz teflona, za vrhunsko odpornost proti koroziji.

• Robustno polimerno ohišje vzdržljivo na udarce.

• Integriran visokozmogljiv sistem prezračevanja za odstranjevanje hlapov in pomoč pri ohlajevanju posod.

Proizvajalec

CEM

Dobavni rok

1 mesec

Brošure

CEM MARS 2 brošura

Literatura

Literatura

Povezava na spletno stran proizvajalca

MARS 2

Opis

Tehnologija One-Touch  

Izbirate lahko med vnaprej nameščenimi metodami za pripravo vzorcev.  

Vsaka metoda vključuje priporočeno količino vzorca, vrsto in količino kisline. Sistem samodejno zazna tip posode, ki jo uporabljate, zazna število posod in temu ustrezno prilagodi moč za najbolj optimalni razklop vzorcev. 

 

Napredni senzorji 

Boljši nadzor zagotavlja boljše rezultate.  

MARS 2 uporablja vrsto integriranih, brezkontaktnih senzorjev, ki zagotavljajo najbolj natančno dovajanje moči in meritve temperature. Senzorji na dnu komore zaznajo število posod in na podlagi tega določijo moč mikrovalovČe pripravimo le nekaj vzorcev, se začetna moč močno zmanjša, velike serije pa bodo prejele več moči. Ta nadzor je edinstven za družino MARS sistemov in zagotavlja najboljši nadzor nad delovanjem. Drugi senzorji prepoznajo tip posode in preverijo ali je tip posode primeren za vaš vzorec. Temperaturni senzor iWave pa zagotavlja natančen brezkontaktni način nadzora temperature. Kombinacija vseh senzorjev zagotavlja najboljši nadzor nad pripravo vaših vzorcev. 

 

Posode MARSXpress 

Posode MARSXpress in MARSXpress Plus so enostavne za uporabo, sestavljene iz samo treh delov, ki se sestavijo v nekaj sekundah, kljub temu pa so dovolj robustne za večino vzorcev. S temi posodami lahko simultano pripravimo več vrst vzorcev hkrati v eni seriji. To znatno poveča produktivnost laboratorijev, ki analizirajo široko paleto vzorcev. V sistemu MARS 2 lahko uporabite posode MARSXpress s prostornino 55 ml ali 75 ml in posode MARSXpress Plus s prostornino 110 ml. 

 

Možnost uporabe različnih insertov 

Inserti za posode omogočajo priročen način priprave vzorcev z malo ali nič čiščenja posod. Na voljo so inserti iz teflona, kvarčnega stekla in stekla. Medtem ko teflon in kvarc veljata za analitsko čista materiala, je steklo zaradi svoje sestave z nekaterimi nečistočami lahko neprimerno za določene namene. 